This site is intended for healthcare professionals

Go to /sign-in page

You can view 5 more pages before signing in

Investigation

Last reviewed dd mmm yyyy. Last edited dd mmm yyyy

Authoring team

Diagnosis of the cause of a lower G.I. bleed on the basis of clinical findings is not sufficiently accurate and hence special investigations are particularly important.

The following protocol may be useful:

  • nasogastric tube aspirate: for evidence of a massive upper GI bleed – a lower GI bleed with haemodynamic instability may be indicative of an upper GI bleeding source (1)
  • sigmoidoscopy: 10% of lower G.I. bleeds occur within reach of a sigmoidoscope

If sigmoidoscopy is negative:

  • colonoscopy:
    • this should be performed as soon as possible
    • emergency preparation of the gut is by administration of 500 ml 10% mannitol, 10 mg metoclopramide and plenty of water; an alternative is picolax
    • observation should be possible in 2-3 hrs

If colonoscopy is negative, consider:

  • technetium scintiscan:
    • good at localising a lesion
    • subsequent management would include arteriography and/ or surgery
  • mesenteric angiography:
    • a sensitive test if the bleeding is brisk, i.e. > 1-2 ml/min

Reference:

  1. Oakland K, Chadwick G, East JE, et al Diagnosis and management of acute lower gastrointestinal bleeding: guidelines from the British Society of GastroenterologyGut 2019;68:776-789.

Create an account to add page annotations

Annotations allow you to add information to this page that would be handy to have on hand during a consultation. E.g. a website or number. This information will always show when you visit this page.

The content herein is provided for informational purposes and does not replace the need to apply professional clinical judgement when diagnosing or treating any medical condition. A licensed medical practitioner should be consulted for diagnosis and treatment of any and all medical conditions.