This site is intended for healthcare professionals

Go to /sign-in page

You can view 5 more pages without signing in

Second (2nd) heart sound (reversed split)

Authoring team

In this condition, P2 occurs before A2.

On expiration, A2 is delayed such that it occurs after P2. Inspiration causes P2 to be delayed and the split is diminished.

Possible causes of a delayed A2 include:

  • electrical delay - left bundle branch block
  • systolic hypertension
  • severe aortic stenosis or HOCM
  • patent ductus arteriosus
  • left heart failure

In patients with aortic stenosis, A2 is often very soft or even absent, in such circumstances there appears to be a single component to the second heart sound.

Note that an early P2 may occur in type B Wolff-Parkinson- White syndrome (1).

Reference:

  • Braunwald E. Heart Disease - A Textbook of Cardiovascular Medicine,WB Saunders.

Create an account to add page annotations

Annotations allow you to add information to this page that would be handy to have on hand during a consultation. E.g. a website or number. This information will always show when you visit this page.

The content herein is provided for informational purposes and does not replace the need to apply professional clinical judgement when diagnosing or treating any medical condition. A licensed medical practitioner should be consulted for diagnosis and treatment of any and all medical conditions.

Connect

Copyright 2024 Oxbridge Solutions Limited, a subsidiary of OmniaMed Communications Limited. All rights reserved. Any distribution or duplication of the information contained herein is strictly prohibited. Oxbridge Solutions receives funding from advertising but maintains editorial independence.