This site is intended for healthcare professionals

Go to /sign-in page

You can view 5 more pages without signing in

NHS Bowel Cancer Screening Programme

Authoring team

NHS Bowel Cancer Screening Programme offers screening every two years to all men and women aged 60 to 74

  • people in the invitation age range are automatically sent an invitation, then bowel screening kit, so they can do the test at home
  • after the first screening test, you will be sent another invitation and screening kit every two years until you reach 74
  • an abnormal result (positive test for haemoglobin in the stool sample) will mean the patient will be offered colonoscopy

Notes (2):

  • on 7 June 2016, Public Health Minister Jane Ellison announced that the faecal immunochemical test (FIT) was to replace the guaiac feacal occult blood test (gFOBt) as the test used for bowel screening:
    • FIT:
      • is easier to use and can be measured more reliably by machine than by the human eye
      • is sensitive to a much smaller amount of blood and can detect cancers more reliably and at an earlier stage
      • has increased sensitivity that enables detection of more pre-cancerours lesions
      • needs only a single faecal sample from a single bowel motion compared to 2 samples from 3 different motions for gFOBt

  • Proportion of target population screened (3):
    • an important objective of the BCSP is to maximise uptake in the invited population - i.e. proportion of the eligible population offered screening and have a result documented
    • the expected effectiveness of the bowel screening programme in reducing bowel cancer mortality requires a minimum uptake of 52%

    • Performance thresholds Acceptable level: >= 52.0% Achievable level: >= 60.0%

Investigating the use of different FIT thresholds and sensitivity for diagnosis of colorectal cancer (4):

  • a study investigated the sensitivity for diagnosis of colorectal cancer using FIT at a threshold of 120 μg/g
    • study stated that the current programme threshold used in England of 120 μg/g was estimated to identify 47.8% of CRC and 25.0% of high-risk adenomas (HRA)
    • the lower the FIT threshold the more likely an individual is to have a positive FIT screening result (and the proportion of false positive results increases)
    • in the analysis by Li et al:
      • for FIT values 80-119 μg/g 1 in 7 individuals with a positive FIT would either have a colorectal cancer or a high risk adenoma
      • for FIT values 40-79 μg/g 1 in 10 individuals with a positive FIT would either have a colorectal cancer or a high risk adenoma
      • for FIT values 20-39 μg/g 1 in 25 individuals with a positive FIT would either have a colorectal cancer or a high risk adenoma
      • for FIT values 10-19 μg/g 1 in 171 individuals with a positive FIT would either have a colorectal cancer or a high risk adenoma
      • comparing different FIT levels with different sensitivities for CRC
        • if a FIT at a level of 20 μg/g was used then the sensitivity would be 82.2% for colorectal cancer
        • if a FIT at a level of 40 μg/g was used then the sensitivity would be 71.1% for colorectal cancer
        • if a FIT at a level of 80 μg/g was used then the sensitivity would be 57.8% for colorectal cancer
        • if a FIT at a level of 120 μg/g was used then the sensitivity would be 47.8% for colorectal cancer

Reference:


Create an account to add page annotations

Annotations allow you to add information to this page that would be handy to have on hand during a consultation. E.g. a website or number. This information will always show when you visit this page.

The content herein is provided for informational purposes and does not replace the need to apply professional clinical judgement when diagnosing or treating any medical condition. A licensed medical practitioner should be consulted for diagnosis and treatment of any and all medical conditions.

Connect

Copyright 2024 Oxbridge Solutions Limited, a subsidiary of OmniaMed Communications Limited. All rights reserved. Any distribution or duplication of the information contained herein is strictly prohibited. Oxbridge Solutions receives funding from advertising but maintains editorial independence.