Sgarbossa criteria for diagnosis of myocardial infarction (MI) in left bundle branch block (LBBB)

Last reviewed dd mmm yyyy. Last edited dd mmm yyyy

Authoring team

Criteria for Sgarbossa ECG algorithm

ECG Finding

Assigned Value

ST-segment elevation >=1 mm in lead with concordant QRS complex

5 points

ST-segment depression >=1 mm in leads V1, V2, or V3

3 points

ST-segment elevation >=5 mm in lead with discordant QRS complex

2 points

ST-segment deviation is measured at the J point. Concordance and discordance of ST segments are determined by comparison to the main direction of the QRS complex.

  • the Sgarbossa algorithm is an effort to derive criteria to facilitate the diagnosis of acute myocardial infarction in patients with left bundle branch block
    • ECG findings from patients with left bundle branch block who were enrolled in the Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries trial (GUSTO-1) to those of a control group of patients with left bundle branch block derived from an outpatient ECG database (1)
      • using the presence of abnormal ST deviation at the J point to delineate 3 ECG criteria (herein termed the Sgarbossa ECG algorithm) (table above), the investigators derived and validated a scoring system for the prediction of acute myocardial infarction in the presence of left bundle branch block
        • a score greater than or equal to 3 had a positive likelihood ratio of 7.8 and a negative likelihood ratio of 0.2
  • a meta-analysis evaluated Sgarbossa algorithm concluded (2)
    • a Sgarbossa ECG algorithm score of greater than or equal to 3, representing greater than or equal to 1 mm of concordant ST elevation or greater than or equal to 1 mm ST depression in leads V1 to V3, is useful for diagnosing acute myocardial infarction in patients who present with left bundle branch block on ECG
      • Sgbarvissa scores >= 3 have a low sensitivity and high specificity for predicting MI in bundle branch block
    • scoring system demonstrates good to excellent overall interobserver variability
    • a score of 2, representing 5 mm or more of discordant ST deviation, demonstrated ineffective positive likelihood ratios
    • a Sgarbossa ECG algorithm score of 0 is not useful in excluding acute myocardial infarction